John Deere H120 Loader

John Deere
Make John Deere
Model H120
Type Front End Loaders for Tractors

Your Preferred Location

Description

  • Compatible with the 1023E and 1025R
  • Quik-Park stands for easy attachment and removal
  • 512 pounds (232 kg) of lift capacity
  • 71.2 in. (1,809 mm) of lift height

Models

Easily remove and mount loader to and from the tractor without tools
Quik-Park™ loader mounting system Quik-Park™ loader mounting system
#

 

The Quik-Park mounting system on the H120 Loader is designed for easy removal and mounting to and from the tractor without tools.

 

Similar to that of the H130 and former 200CX Loaders, the H120’s parking stand is attached to the mast. To lower it into the park position, simply move the joystick to the raise position once the latches are opened.

 

To view a video of how the Quik-Park™ system works click here.

 

NOTE: This video only shows the dismount and mount of the loader without disconnecting the hydraulics. To completely remove the loader, the operator must turn the tractor off, relieve the hydraulics, and then disconnect the hoses from the couplers.

 

Easy removal and mounting (shown on a noncurrent 1026R) Easy removal and mounting (shown on a noncurrent 1026R)
#
Mount to and from the tractor without tools Mount to and from the tractor without tools
#
End-of-pin lubrication on cylinder and pivot pins allows easy access for servicing grease points
Pivot pin Pivot pin

The unique offset head design eliminates cross-pins and cotter pins to retain the pin.

 

A nut ensures the pins remain in position.

 

A lubrication groove provides a path for lubrication.

 

End-of-pin lubrication allows easy access for servicing grease points, which are visible from the side of the loader.

Specifications

  • Key Specs - Boom breakout force: Measured at pivot (Y)<br/>782 kg<br/>1725 lb<br/>Measured at 500 mm ahead of pivot (Z)<br/>595 kg<br/>1311 lb<br/>
  • Key Specs - Bucket rollback force capacity: At ground-level line (ZZ)<br/>867 kg<br/>1911 lb<br/>
  • Key Specs - Clearance at full height - bucket dumped (C): 1371 mm<br/>54 in.
  • Key Specs - Dump angle, degrees (E): -40.1 degree (angle)
  • Key Specs - Lift capacity at full height: Measured at pivot (U)<br/>319 kg<br/>703 lb<br/>Measured at 500 mm ahead of pivot (V)<br/>232 kg<br/>512 lb<br/>
  • Key Specs - Maximum lift height (A): 1809 mm<br/>71.2 in.
  • Key Specs - Rollback angle, degrees (G): 31.2 degree (angle)
  • Loader - Base weight: 246.1 kg
  • Loader - Boom breakout force: Measured at pivot (Y)<br/>782 kg<br/>1725 lb<br/>Measured at 500 mm ahead of pivot (Z)<br/>595 kg<br/>1311 lb<br/>
  • Loader - Bucket angle: Dump angle, degrees (E)<br/>-40.1 degree (angle)<br/>Rollback angle, degrees (G)<br/>31.2 degree (angle)<br/>Dump angle, ground<br/>-114 degree (angle)<br/>
  • Loader - Bucket rollback force capacity: At maximum height (VV)<br/>763 kg<br/>1682 lb<br/>At 59-in. (1500-mm) lift height (XX)<br/>789 kg<br/>1739 lb<br/>At ground-level line (ZZ)<br/>867 kg<br/>1911 lb<br/>
  • Loader - Bucket used: Pin On Materials 1250 mm<br/>49 in.
  • Loader - Bucket weight: 70 kg<br/>155 lb
  • Loader - Cycle times: Loader raise, seconds<br/>4 seconds<br/>Loader lower, seconds<br/>2.5 seconds<br/>Bucket dump, seconds<br/>5.7 (without regen)/2.2 (with regen) seconds<br/>Bucket rollback, seconds<br/>3.5 seconds<br/>
  • Loader - Digging depth (H): -101 mm<br/>-4 in.
  • Loader - Dimensions: Maximum lift height (A)<br/>1809 mm<br/>71.2 in.<br/>At full height - bucket level(B)<br/>1653 mm<br/>65.1 in.<br/>At full height - bucket dumped (C)<br/>1371 mm<br/>54 in.<br/>
  • Loader - Lift capacity at 59 in. (1500 mm): Measured at pivot (W)<br/>331 kg<br/>729 lb<br/>Measured at 500 mm ahead of pivot (X)<br/>262 kg<br/>578 lb<br/>
  • Loader - Lift capacity at full height: Measured at pivot (U)<br/>319 kg<br/>703 lb<br/>Measured at 500 mm ahead of pivot (V)<br/>232 kg<br/>512 lb<br/>
  • Loader - Overall length (I+F), ft (m): 2.6 m<br/>8.6 ft
  • Loader - Reach: At maximum height (D)<br/>571 mm<br/>22.5 in.<br/>At ground level - bucket level (F)<br/>1176 mm<br/>46.3 in.<br/>
  • Tractor - Front tire: 18x8.5-10 4PR R4
  • Tractor - Model: 1025R/1023E/1026R Tractor
  • Tractor - Pump capacity: 3.5 gpm
  • Tractor - Rated pressure: 1987 psi
  • Tractor - Rear tire: 26x12.00-12 4PR R4
  • Tractor - Wheelbase: 1450 mm<br/>57 in.

Copy Set

Easily remove and mount loader to and from the tractor without tools

Quik-Park™ loader mounting system Quik-Park™ loader mounting system
#

 

The Quik-Park mounting system on the H120 Loader is designed for easy removal and mounting to and from the tractor without tools.

 

Similar to that of the H130 and former 200CX Loaders, the H120’s parking stand is attached to the mast. To lower it into the park position, simply move the joystick to the raise position once the latches are opened.

 

To view a video of how the Quik-Park™ system works click here.

 

NOTE: This video only shows the dismount and mount of the loader without disconnecting the hydraulics. To completely remove the loader, the operator must turn the tractor off, relieve the hydraulics, and then disconnect the hoses from the couplers.

 

Easy removal and mounting (shown on a noncurrent 1026R) Easy removal and mounting (shown on a noncurrent 1026R)
#
Mount to and from the tractor without tools Mount to and from the tractor without tools
#

End-of-pin lubrication on cylinder and pivot pins allows easy access for servicing grease points

Pivot pin Pivot pin

The unique offset head design eliminates cross-pins and cotter pins to retain the pin.

 

A nut ensures the pins remain in position.

 

A lubrication groove provides a path for lubrication.

 

End-of-pin lubrication allows easy access for servicing grease points, which are visible from the side of the loader.

Contact

Contact

Consignment

Request a Service

×

Sloan Implement Employee Portal

×

Your session will expire in . If you want to reset this timer, please click OK.

Change Your Preferred Location